000 01897 a2200577 4500
005 20250518020256.0
264 0 _c20190318
008 201903s 0 0 eng d
022 _a1873-2623
024 7 _a10.1016/j.transproceed.2018.04.092
_2doi
040 _aNLM
_beng
_cNLM
100 1 _aCiria, R
245 0 0 _aRescue of Discarded Grafts for Liver Transplantation by Ex Vivo Subnormothermic and Normothermic Oxygenated Machine Perfusion: First Experience in Spain.
_h[electronic resource]
260 _bTransplantation proceedings
_c
300 _a20-24 p.
_bdigital
500 _aPublication Type: Journal Article
650 0 4 _aCold Ischemia
_xmethods
650 0 4 _aExtracorporeal Circulation
_xmethods
650 0 4 _aHumans
650 0 4 _aLiver Transplantation
_xmethods
650 0 4 _aOrgan Preservation
_xmethods
650 0 4 _aPerfusion
_xmethods
650 0 4 _aRewarming
_xmethods
650 0 4 _aSpain
650 0 4 _aTissue Donors
_xsupply & distribution
650 0 4 _aTransplants
_xpathology
700 1 _aAyllon-Teran, M D
700 1 _aGonzález-Rubio, S
700 1 _aGómez-Luque, I
700 1 _aFerrín, G
700 1 _aMoreno, A
700 1 _aSánchez-Frías, M
700 1 _aAlconchel, F
700 1 _aHerrera, C
700 1 _aMartín, V
700 1 _aSánchez-Hidalgo, J M
700 1 _aArjona-Sánchez, Á
700 1 _aOkuda, Y
700 1 _aCabrera, I
700 1 _aBenavente, B
700 1 _aRodriguez, M J
700 1 _aJurado-Martínez, I
700 1 _aDueñas-Jurado, J M
700 1 _aRobles-Arista, J C
700 1 _aRodriguez-Perálvarez, M
700 1 _ade La Mata García, M
700 1 _aLópez-Cillero, P
700 1 _aBriceño, J
773 0 _tTransplantation proceedings
_gvol. 51
_gno. 1
_gp. 20-24
856 4 0 _uhttps://doi.org/10.1016/j.transproceed.2018.04.092
_zAvailable from publisher's website
999 _c29265938