100 | 1 | _aGordon, D J | |
245 | 0 | 0 |
_aProlonged use of a surgical retractor causing neuropathy in an assistant. _h[electronic resource] |
260 |
_bJournal of the Royal College of Surgeons of Edinburgh _cApr 1991 |
||
300 |
_a132 p. _bdigital |
||
500 | _aPublication Type: Case Reports; Journal Article | ||
650 | 0 | 4 | _aAdult |
650 | 0 | 4 | _aHumans |
650 | 0 | 4 |
_aNerve Compression Syndromes _xetiology |
650 | 0 | 4 |
_aOccupational Diseases _xetiology |
650 | 0 | 4 | _aSurgical Instruments |
650 | 0 | 4 | _aSurgical Procedures, Operative |
650 | 0 | 4 |
_aThumb _xinnervation |
650 | 0 | 4 |
_aUlnar Nerve _xinjuries |