100 1 _aWang, Joseph
245 0 0 _aFlow injection amperometric detection of OP nerve agents based on an organophosphorus-hydrolase biosensor detector.
_h[electronic resource]
260 _bBiosensors & bioelectronics
_cMar 2003
300 _a255-60 p.
_bdigital
500 _aPublication Type: Evaluation Study; Journal Article; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, Non-P.H.S.; Validation Study
650 0 4 _aAryldialkylphosphatase
650 0 4 _aBiosensing Techniques
_xinstrumentation
650 0 4 _aCholinesterase Inhibitors
_xanalysis
650 0 4 _aCoated Materials, Biocompatible
_xchemical synthesis
650 0 4 _aElectrochemistry
_xinstrumentation
650 0 4 _aElectrodes
650 0 4 _aEnzymes, Immobilized
650 0 4 _aEquipment Design
650 0 4 _aEsterases
650 0 4 _aFlow Injection Analysis
_xinstrumentation
650 0 4 _aInsecticides
_xanalysis
650 0 4 _aOrganophosphorus Compounds
_xanalysis
650 0 4 _aParaoxon
_xanalysis
650 0 4 _aReproducibility of Results
650 0 4 _aSensitivity and Specificity
700 1 _aKrause, Robin
700 1 _aBlock, Kirstin
700 1 _aMusameh, Mustafa
700 1 _aMulchandani, Ashok
700 1 _aSchöning, Michael J