Aortic regurgitation after transcatheter aortic valve implantation with balloon- and self-expandable prostheses: a pooled analysis from a 2-center experience. [electronic resource]
- JACC. Cardiovascular interventions Mar 2014
- 284-92 p. digital
Publication Type: Clinical Trial; Journal Article; Multicenter Study
1876-7605
10.1016/j.jcin.2013.11.011 doi
Aged, 80 and over Angiography Aortic Valve Insufficiency--diagnosis Confidence Intervals Echocardiography, Transesophageal Female Follow-Up Studies Gated Blood-Pool Imaging Germany--epidemiology Heart Valve Prosthesis Humans Incidence Male Odds Ratio Postoperative Complications Propensity Score Prospective Studies Prosthesis Design Registries Risk Assessment--methods Risk Factors Severity of Illness Index Survival Rate--trends Tomography, X-Ray Computed Transcatheter Aortic Valve Replacement--adverse effects Treatment Outcome