TY - GEN AU - Botta,F AU - Mairani,A AU - Hobbs,R F AU - Vergara Gil,A AU - Pacilio,M AU - Parodi,K AU - Cremonesi,M AU - Coca Pérez,M A AU - Di Dia,A AU - Ferrari,M AU - Guerriero,F AU - Battistoni,G AU - Pedroli,G AU - Paganelli,G AU - Torres Aroche,L A AU - Sgouros,G TI - Use of the FLUKA Monte Carlo code for 3D patient-specific dosimetry on PET-CT and SPECT-CT images SN - 1361-6560 PY - 2014///0611 KW - Air KW - Bone and Bones KW - diagnostic imaging KW - Imaging, Three-Dimensional KW - methods KW - Lung KW - Monte Carlo Method KW - Multimodal Imaging KW - Phantoms, Imaging KW - Positron-Emission Tomography KW - Precision Medicine KW - Radiometry KW - Tomography, Emission-Computed, Single-Photon KW - Tomography, X-Ray Computed KW - Water N1 - Publication Type: Journal Article UR - https://doi.org/10.1088/0031-9155/58/22/8099 ER -