Prevention of ventricular desynchronization by permanent para-Hisian pacing after atrioventricular node ablation in chronic atrial fibrillation: a crossover, blinded, randomized study versus apical right ventricular pacing. [electronic resource]
Producer: 20060525Description: 1938-45 p. digitalISSN:- 1558-3597
- Aged
- Aged, 80 and over
- Arrhythmias, Cardiac -- etiology
- Atrial Fibrillation -- complications
- Atrioventricular Node
- Bundle of His
- Cardiac Pacing, Artificial -- adverse effects
- Catheter Ablation -- adverse effects
- Chronic Disease
- Cross-Over Studies
- Electrocardiography
- Exercise Tolerance
- Feasibility Studies
- Female
- Follow-Up Studies
- Hemodynamics
- Humans
- Male
- Middle Aged
- Mitral Valve Insufficiency -- etiology
- Quality of Life
- Single-Blind Method
- Treatment Outcome
- Tricuspid Valve Insufficiency -- etiology
- Ventricular Dysfunction, Left -- complications
No physical items for this record
Publication Type: Comparative Study; Journal Article; Randomized Controlled Trial
There are no comments on this title.