Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals.
Kim, H C
Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals. [electronic resource] - International endodontic journal Jul 2009 - 593-602 p. digital
Publication Type: Comparative Study; Journal Article
1365-2591
10.1111/j.1365-2591.2009.01553.x doi
Dental Alloys--chemistry
Dental Pulp Cavity--anatomy & histology
Elastic Modulus
Equipment Design
Finite Element Analysis
Humans
Imaging, Three-Dimensional
Materials Testing
Nickel--chemistry
Pliability
Root Canal Preparation--instrumentation
Stress, Mechanical
Surface Properties
Titanium--chemistry
Torsion, Mechanical
X-Ray Microtomography
Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals. [electronic resource] - International endodontic journal Jul 2009 - 593-602 p. digital
Publication Type: Comparative Study; Journal Article
1365-2591
10.1111/j.1365-2591.2009.01553.x doi
Dental Alloys--chemistry
Dental Pulp Cavity--anatomy & histology
Elastic Modulus
Equipment Design
Finite Element Analysis
Humans
Imaging, Three-Dimensional
Materials Testing
Nickel--chemistry
Pliability
Root Canal Preparation--instrumentation
Stress, Mechanical
Surface Properties
Titanium--chemistry
Torsion, Mechanical
X-Ray Microtomography