Dose-volume histograms based on serial intravascular ultrasound: a calculation model for radioactive stents.
Kirisits, C
Dose-volume histograms based on serial intravascular ultrasound: a calculation model for radioactive stents. [electronic resource] - Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology Jun 2001 - 329-37 p. digital
Publication Type: Journal Article
0167-8140
10.1016/s0167-8140(00)00239-5 doi
Aged
Algorithms
Coronary Disease--diagnostic imaging
Dose-Response Relationship, Radiation
Female
Humans
Male
Middle Aged
Radiotherapy Dosage
Radiotherapy Planning, Computer-Assisted
Stents
Ultrasonography, Interventional--methods
Dose-volume histograms based on serial intravascular ultrasound: a calculation model for radioactive stents. [electronic resource] - Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology Jun 2001 - 329-37 p. digital
Publication Type: Journal Article
0167-8140
10.1016/s0167-8140(00)00239-5 doi
Aged
Algorithms
Coronary Disease--diagnostic imaging
Dose-Response Relationship, Radiation
Female
Humans
Male
Middle Aged
Radiotherapy Dosage
Radiotherapy Planning, Computer-Assisted
Stents
Ultrasonography, Interventional--methods